AYAA-3000 Flame & Graphite Furnace Duo System Spectrometer

Select the number of specifications

Please check the product information you want!

Product Detail

AYAA-3000 Atomic Absorption Spectrophotometer

 

 

 

ISO9001 for sales and service

ISO14001 environmental management system

ISO45001 occupational health and safety system certification

Feature

I. It has both flame and graphite furnace atomizers. The two test modes can be automatically switched and automatically matched.

II. Modular design, users can flexibly configure or upgrade according to needs

III. Fully automatic 8-position rotating lighthouse, automatic switching, free setting of work light/preheating light

IV. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search

V. Both flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.

VI. Full titanium burner, stable combustion and fast heat balance

VII. Graphite furnace constant power temperature control achieves uniform graphite tube temperature

VIII. Reliable multiple protection system, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, cooling water monitoring

IX. Powerful operating software and simple human-computer interaction design meet the regulatory requirements of 21CFR part11, authority management, and audit tracking.

Specification

1Optical system

Wavelength range

185nm~910nm auto scan

Grating groove

1800 line/mm

Monochromator

Czerny-Turner type

Spectral bandwidth

0.10.20.41.02.0nm, auto switch

Wavelength accuracy

±0.10nm

Wavelength repeatability

0.05nm

Baseline drift

Static: 0.002A/30min

Detector

Wide spectral range PMT

Spectral resolution

0.3nm

2Light source(Hollow Cathode Lamp)

HCL base

Rotary automatic eight slots

Set individually position for specific element lamp.

Freely set the work light and preheating lamp to maximize the preparation time of the element lamp.

HCL Power supply

Pulse modulated constant current drive

HCL Current range

0~10mA average current

3Atomizer

Flame atomizer(Deuterium arc background corrector)

Detection limit (Cu)

0.003μg/ml

Burner

100mm titanium burner

Precision

RSD≤0.5%(Cu)

Sprayer

High-efficiency metal and glass sprayer

Atomizer chamber

Corrosion resisting plastic chamber

Safety measure

Auto protective, acetylene leak detection and auto switch off

Flame free(graphite furnace) analysis method

Detection limit (Cd)

≤0.3×10-12g

Accuracy 

RSD2%(CdCu)

Heating temperature range

RT~3000℃

4. Flame atomizer analysis

Method

Air-acetylene flame

Concentration calculation

Standard curve, standard addition, interpolation

Repeat times

1~99 timesauto calculation of average, concentration, standard deviation, RSD

Result print

Print test data or final analysis report,or results can be Excel.

Operating system

Windows 10

 

 

5. Flame free analysis method

Measuring method

Peak height and peak area method

Heating method

Advanced vertical constant power graphite furnance

Background correction

Self-reversal deducting background 60 times@1Abs Deuterium arc background corrector 60 times@1Abs

Repeating measurements

1-30 times, calculate the average, and give the standard deviation and relative standard deviation

Print results

Print test data or final analysis report,or results can be Excel.

Software environment

Windows10 operating system, professional software.

 

Software workstation

1. The wizard-style operation interface supports standard operating procedures and method libraries, making it easier for users to manage methods. Independent method optimization interface, adjust method parameters to improve test results, and clear operation process

2. Three-level authority management and audit tracking, complying with GLP regulatory requirements.

3. The test data is displayed in real time during the test process. The original test data of the sample is also saved in the project file and can be viewed and exported to facilitate user traceback of results. The test process and result data can be displayed in custom data formats to facilitate user observation, and import and export data in standard formats.

4. Support common testing methods, including flame method, flame emission method, graphite furnace method, hydride generation method, etc.

5. Support standard curve method and standard addition method. Automatically fit the standard curve, and automatically update the standard curve and test data when the data changes

6. Built-in performance verification program, the results can be saved as project files to facilitate management of instrument status

 

Safety protection

1. Acetylene leakage protection system: 24-hour detection of acetylene concentration inside the instrument and in the working environment. Once the acetylene exceeds the warning concentration, the acetylene gas line will automatically close immediately and prompt an alarm.

2. Real-time flame monitoring: The flame monitor monitors changes in the flame at any time. When an unexpected power outage or incorrect operation causes the flame to go out, the acetylene gas line will automatically close immediately and prompt an alarm.

3. Graphite furnace protection: Monitor the protective gas pressure and cooling water flow at the same time. If there is abnormal fluctuation, the heating will be stopped immediately and an alarm will be prompted.

4. Position identification: and drainage liquid level detection to ensure all-round protection for operators when flames are burning.

 

Parameters

Power

AC 220V/50Hz 150VA (Spectrometer)

Net weight

55kg (Spectrometer)

Gross weight

80kg (Spectrometer)

Instrument size

1110mm(L) × 400mm(W) × 500mm(H) (Spectrometer)

Pack size

1350mm(L) × 600mm(W) × 850mm(H) (Spectrometer)

Working temperature

10~35

Working humidity

≤80%


 


No comment

Product Detail

AYAA-3000 Atomic Absorption Spectrophotometer

 

 

 

ISO9001 for sales and service

ISO14001 environmental management system

ISO45001 occupational health and safety system certification

Feature

I. It has both flame and graphite furnace atomizers. The two test modes can be automatically switched and automatically matched.

II. Modular design, users can flexibly configure or upgrade according to needs

III. Fully automatic 8-position rotating lighthouse, automatic switching, free setting of work light/preheating light

IV. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search

V. Both flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.

VI. Full titanium burner, stable combustion and fast heat balance

VII. Graphite furnace constant power temperature control achieves uniform graphite tube temperature

VIII. Reliable multiple protection system, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, cooling water monitoring

IX. Powerful operating software and simple human-computer interaction design meet the regulatory requirements of 21CFR part11, authority management, and audit tracking.

Specification

1Optical system

Wavelength range

185nm~910nm auto scan

Grating groove

1800 line/mm

Monochromator

Czerny-Turner type

Spectral bandwidth

0.10.20.41.02.0nm, auto switch

Wavelength accuracy

±0.10nm

Wavelength repeatability

0.05nm

Baseline drift

Static: 0.002A/30min

Detector

Wide spectral range PMT

Spectral resolution

0.3nm

2Light source(Hollow Cathode Lamp)

HCL base

Rotary automatic eight slots

Set individually position for specific element lamp.

Freely set the work light and preheating lamp to maximize the preparation time of the element lamp.

HCL Power supply

Pulse modulated constant current drive

HCL Current range

0~10mA average current

3Atomizer

Flame atomizer(Deuterium arc background corrector)

Detection limit (Cu)

0.003μg/ml

Burner

100mm titanium burner

Precision

RSD≤0.5%(Cu)

Sprayer

High-efficiency metal and glass sprayer

Atomizer chamber

Corrosion resisting plastic chamber

Safety measure

Auto protective, acetylene leak detection and auto switch off

Flame free(graphite furnace) analysis method

Detection limit (Cd)

≤0.3×10-12g

Accuracy 

RSD2%(CdCu)

Heating temperature range

RT~3000℃

4. Flame atomizer analysis

Method

Air-acetylene flame

Concentration calculation

Standard curve, standard addition, interpolation

Repeat times

1~99 timesauto calculation of average, concentration, standard deviation, RSD

Result print

Print test data or final analysis report,or results can be Excel.

Operating system

Windows 10

 

 

5. Flame free analysis method

Measuring method

Peak height and peak area method

Heating method

Advanced vertical constant power graphite furnance

Background correction

Self-reversal deducting background 60 times@1Abs Deuterium arc background corrector 60 times@1Abs

Repeating measurements

1-30 times, calculate the average, and give the standard deviation and relative standard deviation

Print results

Print test data or final analysis report,or results can be Excel.

Software environment

Windows10 operating system, professional software.

 

Software workstation

1. The wizard-style operation interface supports standard operating procedures and method libraries, making it easier for users to manage methods. Independent method optimization interface, adjust method parameters to improve test results, and clear operation process

2. Three-level authority management and audit tracking, complying with GLP regulatory requirements.

3. The test data is displayed in real time during the test process. The original test data of the sample is also saved in the project file and can be viewed and exported to facilitate user traceback of results. The test process and result data can be displayed in custom data formats to facilitate user observation, and import and export data in standard formats.

4. Support common testing methods, including flame method, flame emission method, graphite furnace method, hydride generation method, etc.

5. Support standard curve method and standard addition method. Automatically fit the standard curve, and automatically update the standard curve and test data when the data changes

6. Built-in performance verification program, the results can be saved as project files to facilitate management of instrument status

 

Safety protection

1. Acetylene leakage protection system: 24-hour detection of acetylene concentration inside the instrument and in the working environment. Once the acetylene exceeds the warning concentration, the acetylene gas line will automatically close immediately and prompt an alarm.

2. Real-time flame monitoring: The flame monitor monitors changes in the flame at any time. When an unexpected power outage or incorrect operation causes the flame to go out, the acetylene gas line will automatically close immediately and prompt an alarm.

3. Graphite furnace protection: Monitor the protective gas pressure and cooling water flow at the same time. If there is abnormal fluctuation, the heating will be stopped immediately and an alarm will be prompted.

4. Position identification: and drainage liquid level detection to ensure all-round protection for operators when flames are burning.

 

Parameters

Power

AC 220V/50Hz 150VA (Spectrometer)

Net weight

55kg (Spectrometer)

Gross weight

80kg (Spectrometer)

Instrument size

1110mm(L) × 400mm(W) × 500mm(H) (Spectrometer)

Pack size

1350mm(L) × 600mm(W) × 850mm(H) (Spectrometer)

Working temperature

10~35

Working humidity

≤80%


 


AYAA-3000 Flame & Graphite Furnace Duo System Spectrometer
Long press to look detail
Long by picture save/share
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

AYAA-3000 Flame & Graphite Furnace Duo System Spectrometer

Enquiry
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

ADDRESS

 

No. 609, High tech Torch Street, Qingshanhu District, Nanchang City, Jiangxi Province

          

     David                  Mabel              James

CONTACT

 

Ph:  +86 19318553935

         +86 18170839926                            +86 18079100967

     

Mail:  james@jx-aiyi.com

            mabel@jx-aiyi.com

            david@jx-aiyi.com

         
           

NEWSLETTER

  • E-mail

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Copyright © 2024  All Rights Reserved.

ABOUT         CONTACT         PRODUCT

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了