+86 18170839926

图片展示
Search
Hello! login Register
Whats App
Qrcode
扫一扫关注
Whats App
Qrcode
PH
+86 18170839926 
Mail
mabel@jx-aiyi.com

This Graphite Furnace Atomic Absorption Spectrometer (GFAAS) is designed for ultra-trace metal analysis with high accuracy and stability. It features a total reflection optical system with full-wavelength achromatic correction, automatic wavelength scanning, and peak searching for precise element detection. The system supports dual background correction technologies, including Deuterium lamp correction and self-absorption background correction, effectively eliminating interference from complex m

AY-1000SG Graphite Furnace Atomic Absorption Spectrometer

Select the number of specifications

Please check the product information you want!

Product Detail

Feature

1. Full reflection optical system, full band achromatic, automatic wavelength scanning, automatic peak search.

2. Deuterium lamp background reduction, self-absorption background reduction.

3. Uniquely designed all-titanium burner, stable combustion, fast thermal equilibrium speed.

4. Automatic adjustment of negative high voltage, lamp current, element lamp position to adjust energy at will, automatic gas leakage and flameout protection. 

  • 3 hollow cathode lamp holders. Automatic control system, can automatically scan wavelength.
  • 1 element lamp is working, and the other two element lamps are preheated.

5. Graphite furnace heating: users can freely set the heating curve according to their needs.

6. Advanced graphite furnace constant power temperature control design: the temperature of the graphite tube is uniform, and the working temperature of the graphite tube maintains good dynamic stability to ensure the accuracy of the analysis.

 

Specification

1.Optical system
Wavelength range185nm—910nm auto scan
Grating groove1800 line/mm
MonochromatorCzerny-Turner type
Spectral bandwidth0.1、0.2、0.4、1.0、2.0nm, auto switch
Wavelength accuracy±0.10nm
Wavelength repeatability0.05nm
Baseline driftStatic: 0.002A/30min, dynamic: 0.006 A/30min
DetectorWide spectral range PMT
Spectral resolutionAble to resolve the emission peaks of manganese HCL at 279.5nm and 279.8nm. The energy at the valley between the two peaks is below 20%.
2.Light source system
Lamp holder3 lamp holders
Lamp power supply mode400Hz square wave pulse
Lamp current adjustment range2-10mA average current
3. Atomization system
Flameless (graphite furnace) analysis method
Characteristic quantity (Cd)<0.5x10-129
Detection limit (Cd)<0.4x10-129
PrecisionRSD<2%
Heating rangeRoom temperature~2800℃
Heating methodAdvanced longitudinal constant power graphite furnace heating method
Heating temperature control methodSafe and reliable high-precision constant power temperature control method
Heating methodRamp heating, step heating, PID controlled high power heating, user-defined PID control curve heating
Temperature control accuracy<1%
Background correction
Deuterium lamp background correction>60 times@1Abs
Self-absorption background correction>60 times@1Abs
Atomic Absorption Method with Hydride Generator
4. Flameless (graphite furnace) analysis method
Measurement methodGraphite furnace peak height method, graphite furnace peak area method
Background correctionDeuterium lamp background correction greater than 60 times, self-absorption deduction background greater than 60 times
Number of repeated measurements1-30 times, calculate the average value, give the standard deviation and relative standard deviation
Result printingPrint test data or final analysis report. Results can be exported to Excel worksheet
Software environmentWindows XP/Windows 7 operating system, Chinese professional software






 


 

 


No comment

Product Detail

Feature

1. Full reflection optical system, full band achromatic, automatic wavelength scanning, automatic peak search.

2. Deuterium lamp background reduction, self-absorption background reduction.

3. Uniquely designed all-titanium burner, stable combustion, fast thermal equilibrium speed.

4. Automatic adjustment of negative high voltage, lamp current, element lamp position to adjust energy at will, automatic gas leakage and flameout protection. 

  • 3 hollow cathode lamp holders. Automatic control system, can automatically scan wavelength.
  • 1 element lamp is working, and the other two element lamps are preheated.

5. Graphite furnace heating: users can freely set the heating curve according to their needs.

6. Advanced graphite furnace constant power temperature control design: the temperature of the graphite tube is uniform, and the working temperature of the graphite tube maintains good dynamic stability to ensure the accuracy of the analysis.

 

Specification

1.Optical system
Wavelength range185nm—910nm auto scan
Grating groove1800 line/mm
MonochromatorCzerny-Turner type
Spectral bandwidth0.1、0.2、0.4、1.0、2.0nm, auto switch
Wavelength accuracy±0.10nm
Wavelength repeatability0.05nm
Baseline driftStatic: 0.002A/30min, dynamic: 0.006 A/30min
DetectorWide spectral range PMT
Spectral resolutionAble to resolve the emission peaks of manganese HCL at 279.5nm and 279.8nm. The energy at the valley between the two peaks is below 20%.
2.Light source system
Lamp holder3 lamp holders
Lamp power supply mode400Hz square wave pulse
Lamp current adjustment range2-10mA average current
3. Atomization system
Flameless (graphite furnace) analysis method
Characteristic quantity (Cd)<0.5x10-129
Detection limit (Cd)<0.4x10-129
PrecisionRSD<2%
Heating rangeRoom temperature~2800℃
Heating methodAdvanced longitudinal constant power graphite furnace heating method
Heating temperature control methodSafe and reliable high-precision constant power temperature control method
Heating methodRamp heating, step heating, PID controlled high power heating, user-defined PID control curve heating
Temperature control accuracy<1%
Background correction
Deuterium lamp background correction>60 times@1Abs
Self-absorption background correction>60 times@1Abs
Atomic Absorption Method with Hydride Generator
4. Flameless (graphite furnace) analysis method
Measurement methodGraphite furnace peak height method, graphite furnace peak area method
Background correctionDeuterium lamp background correction greater than 60 times, self-absorption deduction background greater than 60 times
Number of repeated measurements1-30 times, calculate the average value, give the standard deviation and relative standard deviation
Result printingPrint test data or final analysis report. Results can be exported to Excel worksheet
Software environmentWindows XP/Windows 7 operating system, Chinese professional software






 


 

 


AY-1000SG Graphite Furnace Atomic Absorption Spectrometer
This Graphite Furnace Atomic Absorption Spectrometer (GFAAS) is designed for ultra-trace metal analysis with high accuracy and stability. It features a total reflection optical system with full-wavelength achromatic correction, automatic wavelength scanning, and peak searching for precise element detection. The system supports dual background correction technologies, including Deuterium lamp correction and self-absorption background correction, effectively eliminating interference from complex m
Long press to look detail
Long by picture save/share
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

AY-1000SG Graphite Furnace Atomic Absorption Spectrometer

Enquiry
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

ADDRESS

 

No. 609, High tech Torch Street, Qingshanhu District, Nanchang City, Jiangxi Province

          

     David                  Mabel              James

CONTACT

 

Ph:  +86 19318553935

         +86 18170839926                            +86 18079100967

     

Mail:  james@jx-aiyi.com

            mabel@jx-aiyi.com

            david@jx-aiyi.com

         
           

NEWSLETTER

  • E-mail

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Copyright © 2024  All Rights Reserved.

ABOUT         CONTACT         PRODUCT

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了