1. Chemical properties
Composition: It is composed of 6% cyanopropylphenyl and 94% dimethylpolysiloxane. The cyanopropylphenyl part is bonded to the dimethylpolysiloxane chain, giving it a unique separation ability.
Stability:
- Thermal stability: It can be used in a wide temperature range of -20℃ to 260℃ (or 280℃), which can meet different analytical needs.
- Chemical stability: It is inert to active compounds, reduces adsorption and decomposition, and improves analytical accuracy.
Interfacial activity: It forms reversible adsorption between different phases, which is suitable for analyzing a variety of compounds, including volatile organic compounds, residual solvents, pesticides, etc.
2. Physical properties
Temperature application range: Usually -20℃ to 260℃ (or 280℃), which can meet different analytical needs.
- Column bleed rate: Ultra-low column bleed, improving analytical accuracy and column life.
- Diverse specifications: Provide a variety of lengths (15m, 30m, 60m, etc.), inner diameters (0.25mm, 0.32mm, 0.53mm) and film thicknesses (0.25μm, 1.00μm, etc.) to meet different analysis needs.
3.Product Specifications
| Length (m) | ID(mm) | Film thickness (μm) | Operating temperature (°C) |
| 30 | 0.25 | 0.25 | 0 to 290/300 |
| 30 | 0.25 | 0.50 | 0 to 290/300 |
| 30 | 0.25 | 1.40 | 0 to 290/300 |
| 60 | 0.25 | 1.40 | 0 to 290/300 |
| 30 | 0.32 | 0.50 | 0 to 290/300 |
| 30 | 0.32 | 1.00 | 0 to 290/300 |
| 30 | 0.32 | 1.80 | 0 to 290/300 |
| 60 | 0.32 | 1.00 | 0 to 290/300 |
| 60 | 0.32 | 1.80 | 0 to 290/300 |
| 30 | 0.53 | 1.00 | 0 to 290/300 |
| 30 | 0.53 | 3.00 | 0 to 290/300 |
| 60 | 0.53 | 3.00 | 0 to 290/300 |
Performance Highlights
- Excellent resolution of volatile organic compounds (VOCs), residual solvents (per ICH/ChP guidelines), pesticides, and light hydrocarbons
- High thermal and chemical stability; high batch-to-batch reproducibility
- Compatible with FID, ECD, NPD, and MS detectors
Typical Applications
- Pharmaceutical quality control - analysis of residual solvents in APIs and finished products
- Environmental monitoring - halogenated VOCs, BTEX, and PCBs in air/water samples
- Petrochemical - detailed screening of hydrocarbons and solvents
- Cosmetics and fragrances - analysis of trace solvents and fragrance components
Case Studies
Baseline separation of residual methanol, ethanol, and acetone in dexamethasone sodium phosphate in 8 minutes using a 30 m × 0.25 mm × 1.40 µm column to meet pharmacopeia separation criteria.
Why choose this column?
- Mid-polar 624 phase = one column for analyzing polar and nonpolar volatile compounds
- Ultra-low bleed for clean MS background
- Available in a variety of sizes; custom sizes available upon request
- Proven in pharmaceutical, environmental, food, and petrochemical laboratories worldwide
Click the inquiry above or send us an email to get your customized solution.