Features
1.Adopts total reflection optics and all-wavelength achromatic design. Equipped with automatic wavelength scanning and peak search functions to ensure accurate positioning and improve the performance of atomic absorption spectrometer.
2.The uniquely designed all-titanium burner provides stable flame combustion and rapid thermal equilibration, making it ideal for high-throughput flame AA spectroscopy applications.
3.Automatically adjusts negative high voltage, lamp current, and element lamp position to maximize light energy. Equipped with automatic gas leakage and flame extinguishing protection system to ensure safe and reliable operation.
4.The 8-lamp turntable (optionally can be equipped with 2 high-performance lamps) is fully automatic and can accurately adjust the hollow cathode lamp to the optimal position. The position of specific element lamps can be pre-set and the function of operation/preheat lamp can be freely set, greatly reducing the preparation time of element lamps.
5.The system can be upgraded to a graphite furnace atomic absorption spectrometer, which increases the flexibility of trace element analysis and extends the application range of the instrument from routine testing to ultra-trace detection.
Specification
1.Optical system
Wavelength range | 185nm—910nm auto scan |
Grating groove | 1800 line/mm |
Monochromator | Czerny-Turner type |
Spectral bandwidth | 0.1、0.2、0.4、1.0、2.0nm, auto switch |
Wavelength accuracy | ±0.10nm |
Wavelength repeatability | 0.05nm |
Baseline drift | Static: 0.002A/30min, dynamic: 0.006 A/30min |
Detector | Wide spectral range PMT |
Spectral resolution | Able to resolve the emission peaks of manganese HCL at 279.5nm and 279.8nm. The energy at the valley between the two peaks is below 20%. |
2.Light source
HCL base | 8 slots for HCLs |
HCL power supply | 400Hz square wave |
HCL current range | 2—10mA average current |
3.Atomizer
Flame atomizer |
Detection limit (Cu) | 0.003μg/ml |
Burner | 100mm titanium burner |
Precision | RSD≤0.5% |
Sprayer | High-efficiency metal and glass sprayer |
Atomizer chamber | Corrosion resisting plastic chamber |
Safety measure | Auto protective, acetylene leak detection and auto switch off |
4.Flame atomizer analysis
Method | Air – acetylene flame |
Concentration calculation | Standard curve, standard addition, interpolation |
Repeat times | 1~99 times,auto calculation of average, concentration, standard deviation, RSD |
Result print | Print of test data and final report. The result can export to Word format |
Operating system | Windows XP/Win7 |
Parameters
Power | AC 220V/50Hz 150VA (Spectrometer) |
Net weight | 55kg (Spectrometer) |
Gross weight | 80kg (Spectrometer) |
Instrument size | 1110mm(L) × 400mm(W) × 500mm(H) (Spectrometer) |
Pack size | 1350mm(L) × 600mm(W) × 850mm(H) (Spectrometer) |
Working temperature | 10~35℃ |
Working humidity | ≤80% |