GC-MS (Gas Chromatography-Mass Spectrometry) is a high-performance analytical instrument that combines gas chromatography and mass spectrometry technologies for the separation and identification of complex mixtures of compounds. It has demonstrated excellent performance in accurate chemical composition analysis and is widely used in environmental monitoring, food safety, pharmaceutical research, petrochemical analysis and life sciences.

 GC91-MS10 Gas Chromatography-Mass Spectrometry (Gc-Ms)

Select the number of specifications

Please check the product information you want!

Product Detail

Main features


1. Temperature and pressure control accuracy of GC is ensuring good test repeatability

2. Wide temperature RF power supply can better adapt to various laboratory environments and provide better stability

3. High-precision all-metal molybdenum quadrupole ensures good mass spectral resolution

4. Quadrupole mass analyzer with pre-quadrupole can effectively reduce the pollution of the quadrupole

5. Electron multiplier with high-energy conversion dynode guarantees excellent sensitivity

6. High-performance turbomolecular pump have high pumping speed, stable operation and long life, provides an excellent vacuum environment for mass spectrometry

7. High-temperature inert ion source for efficient ionization is reducing pollution, equipped with two long-life filaments, providing double the use time

8. It can be configured with automatic sampler, purge and trap instrument, thermal desorption instrument, headspace sampler, etc. for the analysis of samples in various states.



Product parameters


Column oven

Procedure heating

Better than 6 order 7 platform

Operating temperature range

RT +5℃ to 450℃

Temperature setting accuracy

0.01℃

Highest programmed heating rate

120℃/min

Cooling speed

300℃~50℃ less than 300s

 

Split/splitless capillary column injection port

Shunt mode

Splunt, no shunt, pulse not shunt, pulse shunt

Maximum operating temperature

400℃

Setting range of column head pressure

0100psi

Accuracy of column head pressure control:

0.01psi

Flow control

Constant flow, constant pressure, program flow flow, program boost, etc

Heating area

More than 6 areamax 400℃

Autosampler

Optional

 

Mass spectrometer detector

Mass number range

1.51000 amu

Maximum scanning speed

10,000 amu/s

Sensitivity

1pg, OFN, S/N 150:1

Quality stability

>±0.1amu/24 hours

EI ion source

Inert with dual filament

Ionization energy

10100eV

Ion source temperature

150350℃

GCMS interface temperature

100350℃

Mass analyzer

With a pre-quadrupole and high-precision all-metal quadrupole rod, the temperature stability can be guaranteed without temperature control

Scan function

Full scan, selective ion monitoring, full scan, and selective ion synchronous monitoring, alternating scanning

Detection system

Electronic multiplier with a high-energy tap pole

Vacuum system

Mechanical pump pump 4m³ / h and high performance turbine molecular pump 90 L/s

 


No comment

Product Detail

Main features


1. Temperature and pressure control accuracy of GC is ensuring good test repeatability

2. Wide temperature RF power supply can better adapt to various laboratory environments and provide better stability

3. High-precision all-metal molybdenum quadrupole ensures good mass spectral resolution

4. Quadrupole mass analyzer with pre-quadrupole can effectively reduce the pollution of the quadrupole

5. Electron multiplier with high-energy conversion dynode guarantees excellent sensitivity

6. High-performance turbomolecular pump have high pumping speed, stable operation and long life, provides an excellent vacuum environment for mass spectrometry

7. High-temperature inert ion source for efficient ionization is reducing pollution, equipped with two long-life filaments, providing double the use time

8. It can be configured with automatic sampler, purge and trap instrument, thermal desorption instrument, headspace sampler, etc. for the analysis of samples in various states.



Product parameters


Column oven

Procedure heating

Better than 6 order 7 platform

Operating temperature range

RT +5℃ to 450℃

Temperature setting accuracy

0.01℃

Highest programmed heating rate

120℃/min

Cooling speed

300℃~50℃ less than 300s

 

Split/splitless capillary column injection port

Shunt mode

Splunt, no shunt, pulse not shunt, pulse shunt

Maximum operating temperature

400℃

Setting range of column head pressure

0100psi

Accuracy of column head pressure control:

0.01psi

Flow control

Constant flow, constant pressure, program flow flow, program boost, etc

Heating area

More than 6 areamax 400℃

Autosampler

Optional

 

Mass spectrometer detector

Mass number range

1.51000 amu

Maximum scanning speed

10,000 amu/s

Sensitivity

1pg, OFN, S/N 150:1

Quality stability

>±0.1amu/24 hours

EI ion source

Inert with dual filament

Ionization energy

10100eV

Ion source temperature

150350℃

GCMS interface temperature

100350℃

Mass analyzer

With a pre-quadrupole and high-precision all-metal quadrupole rod, the temperature stability can be guaranteed without temperature control

Scan function

Full scan, selective ion monitoring, full scan, and selective ion synchronous monitoring, alternating scanning

Detection system

Electronic multiplier with a high-energy tap pole

Vacuum system

Mechanical pump pump 4m³ / h and high performance turbine molecular pump 90 L/s

 


GC91-MS10 Gas Chromatography-Mass Spectrometry (Gc-Ms)
GC-MS (Gas Chromatography-Mass Spectrometry) is a high-performance analytical instrument that combines gas chromatography and mass spectrometry technologies for the separation and identification of complex mixtures of compounds. It has demonstrated excellent performance in accurate chemical composition analysis and is widely used in environmental monitoring, food safety, pharmaceutical research, petrochemical analysis and life sciences.
Long press to look detail
Long by picture save/share
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

GC91-MS10 Gas Chromatography-Mass Spectrometry (Gc-Ms)

Enquiry
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

ADDRESS

 

No. 609, High tech Torch Street, Qingshanhu District, Nanchang City, Jiangxi Province

          

     David                  Mabel              James

CONTACT

 

Ph:  +86 19318553935

         +86 18170839926                            +86 18079100967

     

Mail:  james@jx-aiyi.com

            mabel@jx-aiyi.com

            david@jx-aiyi.com

         
           

NEWSLETTER

  • E-mail

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Copyright © 2024  All Rights Reserved.

ABOUT         CONTACT         PRODUCT

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了